© Physik Instrumente (PI) GmbH & Co. KG
Auf der Römerstr. 1 76228 Karlsruhe, Germany
Tel. +49 721 4846-0 Fax: +49 721 4846-299
[email protected] www.pi.ws
PZ214Equ Quick Guide
E-517 Digital Piezo Controller
Operation Module
Release: 1.0.0 Date: 07.01.2009
This document describes the following
products:
E-517.i3
Digital Piezo Controller Operation Module, TCP/IP,
USB, RS-232, 3 Channels
E-517.i1
Digital Piezo Controller Operation Module, TCP/IP,
USB, RS-232, 1 Channel
Przeglądanie stron 0
1 2 3 4 5 6 ... 75 76

Podsumowanie treści

Strona 1 - ■ E-517.i1

© Physik Instrumente (PI) GmbH & Co. KG Auf der Römerstr. 1 ⋅ 76228 Karlsruhe, Germany Tel. +49 721 4846-0 ⋅ Fax: +49 721 4846-299 info@pi

Strona 2

Introduction ! CAUTION Your system will be fully calibrated before being shipped. If you have informed PI about your application, calibration is d

Strona 3

Introduction 1.4 Model Survey The following E-517 models are available: E-517.i3 Interface / Display Module, 24 Bit D/A, TCP/IP, USB, RS-232, 3

Strona 4

Introduction MDR connector for Digital In/Out socket, consisting of: 4347 MDR connector, 14-pol, RM 1.27 4348 MDR cover 14-pol E-517.CD Distr

Strona 5 - Contents

Introduction 1.7 Software Description Operating system details: "Windows" stands for 2000, XP and Vista "Linux" stands

Strona 6

Introduction Software ToolSupported Operating SystemShort Description Recommended forPIMikroMove™ Windows PIMikroMove™ permits you to start your m

Strona 7 - 1 Introduction

First Steps 2 First Steps 2.1 Installing the Software on the Host PC Windows operating systems: 1 Insert the E-517 CD in your host PC. 2 If th

Strona 8

First Steps program. Proceed as follows to create a parameter file: 1 Power on the system. Find details in a dedicated section (p. 31). 2 Start

Strona 9 - 1.3 Safety Precautions

First Steps to copy the values of protected parameters from the Edit Mask column to the controller, enter the password "advanced" to swit

Strona 10 - CAUTION

First Steps 3 Start PIMikroMove™ on the host PC. It opens with the Start up controller window. 4 Establish a connection to the E-517 from PIMikr

Strona 11 - E-516 COMPATIBILITY NOTE

First Steps 5 Give the E-517 interface / display module control over the output voltage channels of the piezo control electronics by switching the

Strona 13

First Steps Find details in "Modes of Operation" (p. 23). 6 Optionally: Configure the PIMikroMove™ main window: It is recommended to s

Strona 14

First Steps 7 Make some test moves with the individual axes using the controls on the Axes tab card: The first moves should be made in open-loop

Strona 15

First Steps figure below). In closed-loop operation, target positions for the axes are commanded. Enter the target position in the Target field and

Strona 16 - First Steps

Operation 3 Operation NOTES All commands mentioned in the subsections below are PI General Command Set (GCS) commands in the E-517 syntax, provide

Strona 17

Operation 3.1 Front Panel Elements 3.1.1 Front Panel Overview Figure 1: E-517.i3 interface / display module, 3 channels. Single-channel E-517.i1

Strona 18

Operation 3.1.2 Display Screens The individual display screens can be accessed by the trackball (p. 22) on the E-517 front panel. You can check th

Strona 19

Operation CHANNEL SETTING, where you can command motion (in ONLINE mode) or the check current position and voltage (in OFFLINE mode) for individ

Strona 20

Operation In OFFLINE mode, you can check the current voltage and position values on the channel-specific screens. 3.2 Modes of Operation Contr

Strona 21

Operation See "Control Value Generation" in the E-517 User Manual for details. Switching between ONLINE and OFFLINE mode can be done by:

Strona 22

Operation operation omits the servo loop, and the control input directly controls the output voltage of the piezo channel. The slew rate can be inf

Strona 23

Physik Instrumente (PI) GmbH & Co. KG is the owner of the following company names and trademarks: PI®,

Strona 24 - 3.1 Front Panel Elements

Operation On power-on or reboot (with the RBT command), the E-517 copies information from non-volatile memory to volatile memory. The control mode

Strona 25 - 3.1.2 Display Screens

Operation While move commands and trackball settings can be used in parallel to command axis motion, they are not accepted when the wave generator

Strona 26 - 3.1.3 Trackball Functions

Operation Hardware: A piezo stage and an E-500 chassis with one E-505 amplifier module and E-517 (single-channel system). Command String to Send R

Strona 27 - ■ ONLINE mode:

Operation Command String to Send Response Action Performed SVA? A A=+0085.0000 Query the commanded output voltage. It resulted from the last vali

Strona 28 - ■ Open-loop operation:

Operation Command String to Send Response Action Performed ONL 1 1 2 1 3 1 Switch all piezo channels (identifiers 1, 2, 3) to ONLINE mode so that

Strona 29

Operation 3.5 Data Recording 3.5.1 How to Use the Data Recorder The E-517 includes a real-time data recorder. It is able to record several input

Strona 30 - Operation

Operation The data recorder sampling period can be read with the RTR? command. The answer gives the value of the Data Recorder Table Rate parameter

Strona 31

Operation Send: SPA 1 0x05000000 0 to deactivate the digital filter. Close the Command Entry window. 4 Open the Data Recorder window via the E-517

Strona 32

Operation 8 To analyze the recorded data and display it as a Bode frequency response diagram, click on the FFT button in the icon bar above the gr

Strona 33

Operation 3.6 Using Trigger Input and Output It is possible to trigger external devices and to send start/stop signals to the wave generators wit

Strona 34

About This DocumentUsers of This Manual This Quick Guide is designed to help the reader to put the E-517 Digital Piezo Controller Operation Module int

Strona 35

Operation 3.7 How to Work with the Wave Generator Each axis can be controlled by a "wave generator" which outputs user-specified pattern

Strona 36 - Measurements

Operation 3 Stop the wave generator output with WGO or #24 or STP. The simple example below shows how to start periodic motion of the first axis (

Strona 37

Operation 3.8.1 Defining Macros To define a macro command sequence, first activate macro recording mode with the command MAC BEG <macroname>

Strona 38

Operation Example 2: Macro1 now is splitted in two separate macros (macro2 and macro3) because it in not necessary to initialize the E-517 every ti

Strona 39

Operation Macro execution can be stopped from the command line with #24. The STP command stops macro execution only when it is part of the macro.

Strona 40 - 3.7.2 Basic Operation

Operation 3.9 Select Command Set Version Users who have written software for the E-516 interface / display module which is the predecessor of the

Strona 41 - WGO 1 0

Operation 3.10 Updates 3.10.1 Software Updates Updated releases of software and manuals are available for download at www.pi.ws. While the manua

Strona 42 - 3.8.1 Defining Macros

Operation All firmware updates can be made by running the Firmware Update Wizard on the host computer, using the same communication interfaces as f

Strona 43

Operation Figure 3: Select controller to be connected to Firmware Update Wizard www.pi.ws E-517 PZ214Equ Release 1.0.0 Page 44

Strona 44

Communication 4 Communication 4.1 Interfaces Available The E-517 can be controlled from a host computer (not included) with ASCII commands sent v

Strona 45

Contents 1 Introduction 3 1.1 How to Use the E-517 Documentation ...4 1.2 Prescribed Use...

Strona 46

Communication NOTES All commands mentioned in the subsections below are PI General Command Set (GCS) commands in the E-517 syntax, provided by the

Strona 47

Communication GPADR: gives the device address to be used for GPIB (IEEE 488) communication, default is 4 also accessible as GPIB Address paramet

Strona 48

Communication 4.3 TCP/IP Connection The TCP/IP connection is available on the E-517 front panel of the controller, via the RJ 45 socket with the n

Strona 49 - 4 Communication

Communication First, make sure that the proper startup behaviour is set (see Note above). Then, if a network with DHCP server is available, connect

Strona 50 - Communication

Communication 4.3.2 PC with Ethernet Card The IP address and IP mask settings of PC and E-517 must be compatible with each other in the following

Strona 51

Communication 3 In the Properties window of the LAN connection, click on Internet Protocol (TCP/IP). 4 In the Internet Protocol (TCP/IP) Properties

Strona 52 - ■ Network with DHCP server

Communication Adapt IP address and Subnet mask; do not change the Default gateway setting Press OK Figure 5: Internet Protocol (TCP/IP) Pr

Strona 53

Communication Do not use "255", and do not change the port setting (must always be 50000). 3 Close the connection. 4 Connect the E-517

Strona 54

Communication Figure 6: RS-232 configuration of the host PC side in PIMikroMove™ If you have established a connection and want to change the curr

Strona 55

Communication 4.5 USB Connection The USB interface is available on the front panel of the E-517 via the type B USB socket. Use the included USB ca

Strona 56

3.10.1 Software Updates ... 42 3.10.2 Firmware Updates ...

Strona 57

Communication 4.6 GPIB (IEEE 488) Parallel Connection The parallel communications bus is accessed via the "GPIB/IEEE488" connector on

Strona 58

Communication If you have established a connection and want to change the currently active address of the E-517, proceed as follows: 1 Use the I

Strona 59 - 4.5 USB Connection

E-517 GCS Commands, Alphabetical Survey 5 E-517 GCS Commands, Alphabetical Survey #5 Request Motion Status #6 Query If Position Has Changed Sin

Strona 60

E-517 GCS Commands, Alphabetical Survey DRC Set Data Recorder Configuration DRC? Get Data Recorder Configuration DRR? Get Recorded Data Values

Strona 61

E-517 GCS Commands, Alphabetical Survey ONT? Get On Target State OVF? Get Overflow State PLM Set High Position Soft Limit PLM? Get High Posi

Strona 62 - Alphabetical Survey

E-517 GCS Commands, Alphabetical Survey TIO? Tell Digital I/O Lines TMN? Get Minimum Commandable Position TMX? Get Maximum Commandable Positio

Strona 63

E-517 GCS Commands, Alphabetical Survey WGC Set Number Of Wave Generator Cycles WGC? Get Number Of Wave Generator Cycles WGO Set Wave Generato

Strona 64

TTroubleshooting 6 Troubleshooting Communication with controller does not work Communication cable is wrong or defective ⇒ Check cable. Does it wo

Strona 65

TTroubleshooting ⇒ The first time you connect over the USB interface, be sure you are logged on the PC as a user having administrator rights. After

Strona 66

TTroubleshooting be identical or the parameters of the GEMAC interpolation circuit must be adapted, see "GEMAC Parameter Adjustment" for

Strona 67 - 6 Troubleshooting

Introduction 1 Introduction Low-Noise 24-bit D/A Converter Sample Rate 25 kHz TCP/IP, USB, IEEE 488 and RS-232 Interfaces 6-Digit Disp

Strona 68 - Cable not connected properly

TTroubleshooting Incorrect control mode of the piezo channel ⇒ Check the current control mode using the ONL? command or on the main screen of the E

Strona 69 - Wrong axis commanded

TTroubleshooting When using the wave generator, it is recommended to reduce the frequency and/or the amplitude and/or the output duration to avoid

Strona 70 - TTroubleshooting

Customer Service 7 Customer Service Call your PI representative or write to [email protected]; please have the following information about your system re

Strona 71

Old Equipment Disposal 8 Old Equipment Disposal In accordance with EU directive 2002 / 96 / EC (WEEE), as of 13 August 2005, electrical and electr

Strona 72 - 7 Customer Service

Technical Data 9 Technical Data 9.1 Specifications E-517.i1 E-517.i3 Function Digital operation module Digital operation module Channels 1

Strona 73 - 8 Old Equipment Disposal

Technical Data 9.2 Pin Assignments 9.2.1 Digital In/Out Socket Connector type: MDR14 Pin Signal Function 1 GND GND 2 nc not connected 3 out

Strona 74 - 9 Technical Data

Technical Data 9.2.3 Main Connector Connector type: 32-pin connector, DIN 41612 Row Pin a Pin c 1 AGND AGND 2 IN: ch1 OUT: ch1 3 IN: ch2 OU

Strona 75 - 9.2 Pin Assignments

Introduction 1.1 How to Use the E-517 Documentation This Quick Guide enables you to put the E-517 into operation for the first time and gives you

Strona 76 - Technical Data

Introduction 1.2 Prescribed Use The E-517 Digital Piezo Controller Operation Module is designed for installation in E-500/E-501, E-471 and E-481 m

Komentarze do niniejszej Instrukcji